S9700堆叠主控板注册失败
问题描述
某企业用,用S9706 V200R008C00SPC500 堆叠,发现备框备用主控板不能注册
告警信息
Chassis 2 8槽位单板状态为Unregistered,如下:
===============display device===============
==================================================
Chassis 1 (Master Switch)
S9706's Device status:
Slot Sub Type Online Power Register Status Role
-------------------------------------------------------------------------------
1 - EH1D2G24SEC0 Present PowerOn Registered Normal NA
2 - EH1D2G48TFA0 Present PowerOn Registered Normal NA
3 - EH1D2G48TFA0 Present PowerOn Registered Normal NA
7 - EH1D2SRUC000 Present PowerOn Registered Normal Master
1 EH1D2VS08000 Present PowerOn Registered Normal NA
8 - EH1D2SRUC000 Present PowerOn Registered Normal Slave
1 EH1D2VS08000 Present PowerOn Registered Normal NA
PWR1 - - Present PowerOn Registered Normal NA
PWR2 - - Present PowerOn Registered Normal NA
CMU1 - EH1D200CMU00 Present PowerOn Registered Normal Master
FAN1 - - Present PowerOn Registered Normal NA
FAN2 - - Present PowerOn Registered Normal NA
Chassis 2 (Standby Switch)
S9706's Device status:
Slot Sub Type Online Power Register Status Role
-------------------------------------------------------------------------------
1 - EH1D2G24SEC0 Present PowerOn Registered Normal NA
2 - EH1D2G48TFA0 Present PowerOn Registered Normal NA
3 - EH1D2G48TFA0 Present PowerOn Registered Normal NA
7 - EH1D2SRUC000 Present PowerOn Registered Normal Master
1 EH1D2VS08000 Present PowerOn Registered Normal NA
8 - - Present PowerOn Unregistered - Slave
PWR1 - - Present PowerOn Registered Normal NA
PWR2 - - Present PowerOn Registered Normal NA
CMU1 - EH1D200CMU00 Present PowerOn Registered Normal Master
FAN1 - - Present PowerOn Registered Normal NA
FAN2 - - Present PowerOn Registered Normal NA
<SIMT>
处理过程
1.首先检查版本是否支持该EH1D2SRUC板卡,手册板卡和版本配套关系显示支持

2.检查板卡无弯针,拔插单板仍然不能注册。
3.查看设备相关reason 和日志信息
Jun 17 2016 12:20:51 SIMT CSSM/2/CSSVS08CONNECTERR:OID 1.3.6.1.4.1.2011.5.25.183.3.3.2.15 The connection between CSS port 1/7/0/6 and 2/7/0/6 is incorrect. 1/7/0/6 belongs to group 2 of slot1/7 and should be connected to a port in group 2 of slot2/8. 2/7/0/6 belongs to group 2 of slot2/7 and should be connected to a port in group 2 of slot1/8. (group 1: 1-4 group 2: 5-8)
The MPU chassis[1] board[8]'s reset time is 2 in total. Detailed information:
-- 1. 2016/06/17 12:20:37, Reset No.: 2
Reason: Reset for no right link to the remote chassis
-- 2. 2016/06/17 12:04:59, Reset No.: 1
Reason: Reset for no right link to the remote chassis
Info: The MPU chassis[2] board[7] does not have reset records.
The MPU chassis[2] board[8]'s reset time is 1 in total. Detailed information:
-- 1. 2016/06/17 12:20:27, Reset No.: 1
Reason: Reset for the CSS card is pullout
发现2/8重启原因是子卡拔出。尝试板卡下电后拔插子卡,故障解决,单板能正常注册。
根因
由于子卡没有插好,触发母板的使用限制,最终导致板卡不能正常注册

解决方案
板卡下电重新拔插子卡,问题解决
建议与总结
板卡不能注册首先检查版本是否支持,对板卡的使用限制特别要注意。