S7703风扇声音较大

问题描述

S7703风扇声音比正常运行状态较大。

处理过程

 

1.查看设备健康信息,风扇转速达到70%,稍高于正常转速,但是各个板卡的温度都不高:
[HUAWEI] display health
-------------------------------------------------------------------------------
Slot  Card  Sensor SensorName       Status  Current(V)  Lower(V)    Upper(V)
-------------------------------------------------------------------------------
1     -     3      3.3V             Normal  3.3320      2.6460      3.9592
-     4      1.05V            Normal  1.0780      0.8428      1.2642
-     5      1.25V            Normal  1.2740      0.9996      1.4994
-     6      1.8V             Normal  1.8130      1.4406      2.1560
-     7      2.5V             Normal  2.5088      1.9992      2.9988
-     8      12V              Normal  11.9520     9.5450      14.3590
-     9      1.2V_COMBO       Normal  1.2152      0.9604      1.4406
-     10     2.5V_MII         Normal  2.5088      1.9992      2.9988
4     -     3      3.3V             Normal  3.3124      2.6460      3.9592
-     4      2.5V             Normal  2.5088      1.9992      2.9988
-     5      12V              Normal  12.0350     9.5450      14.3590
-     6      1.8V             Normal  1.7934      1.4406      2.1560
-     7      1.1V             Normal  1.1074      0.8820      1.3230
5     -     3      3.3V             Normal  3.3124      2.6460      3.9592
-     4      2.5V             Normal  2.5088      1.9992      2.9988
-     5      12V              Normal  12.0350     9.5450      14.3590
-     6      1.8V             Normal  1.8032      1.4406      2.1560
-     7      1.1V             Normal  1.1074      0.8820      1.3230
-------------------------------------------------------------------------------
Slot  Card  Sensor  Status   Current(C)  Lower(C) Lower     Upper(C) Upper
Resume(C)          Resume(C)
-------------------------------------------------------------------------------
1     -     1       Normal   34          0        3         67       65
4     -     1       Normal   38          0        3         62       60
5     -     1       Normal   40          0        3         62       60
--------------------------------------------------------------------------
PowerID  Online  Mode   State      Current(A)   Voltage(V)   RealPwr(W)
--------------------------------------------------------------------------
PWR1     Present AC     Supply     0.89         53.66        47.76
PWR2     Present AC     Supply     0.56         53.58        30.00
PoE1     Absent  -      -          -            -            -
-------------------------------------------------------------------------------
FanID   FanNum   Online   Register      Speed       Mode      Airflow
-------------------------------------------------------------------------------
FAN1    [1-2]    Present  Registered    70% (2715)  AUTO      Side-to-Back
1                                 2730
2                                 2700

2.查看光模块信息,发现1/0/20口的光模块温度超过了65度:
[HUAWEI] display transceiver verbose

GigabitEthernet1/0/20 transceiver information:
-------------------------------------------------------------
Common information:
Transceiver Type               :1000_BASE_LX_SFP
Connector Type                 :LC
Wavelength(nm)                 :1310
Transfer Distance(m)           :10000(9um)
Digital Diagnostic Monitoring  :YES
Vendor Name                    :HUAWEI
Vendor Part Number             :02315200
Ordering Name                  :
-------------------------------------------------------------
Manufacture information:
Manu. Serial Number            :EC135100240868
Manufacturing Date             :2013-12-19
Vendor Name                    :HUAWEI
-------------------------------------------------------------
Alarm information:
RX loss of signal
RX power low
-------------------------------------------------------------
Diagnostic information:
Temperature(°C)                      :66
Voltage(V)                            :3.40
Bias Current(mA)                      :29.32
Bias High Threshold(mA)               :100.00
Bias Low  Threshold(mA)               :0.00
Current Rx Power(dBM)                 :-40.00
Default Rx Power High Threshold(dBM)  :-3.00
Default Rx Power Low  Threshold(dBM)  :-24.95
Current Tx Power(dBM)                 :-6.13
Default Tx Power High Threshold(dBM)  :-3.00
Default Tx Power Low  Threshold(dBM)  :-10.00
User Set Rx Power High Threshold(dBM) :-3.00
User Set Rx Power Low Threshold(dBM)  :-24.95
User Set Tx Power High Threshold(dBM) :-3.00
User Set Tx Power Low Threshold(dBM)  :-10.00
-------------------------------------------------------------

3.设备会通过监测单板上光模块的温度对风扇的转速进行调整,将设备的温度控制在合理的范围内。当光模块的温度高于风扇加速温度阈值时,加快风扇转速,加速散热;当光模块温度低于风扇降速温度阈值时,降低风扇转速,节约能源。缺省情况下,风扇降速温度阈值为60℃,风扇加速温度阈值为65℃。设备1/0/20口的光模块温度超过65度,设备加速转速到70%,声音稍大是正常现象。

 

也可以根据实际环境设置风扇减速加速的阈值:
# 配置设备光模块的温度超时67℃时风扇加速,温度低于60℃时风扇减速。
<HUAWEI> system-view
[HUAWEI] set transceiver temperature threshold 60 67 all

 

根因

设备1/0/20口的光模块温度超过65度,设备加速转速到70%,声音稍大是正常现象。

建议与总结

风扇转速过高时,建议同时确认板卡和光模块等器件的温度是否正常,温度过高的器件需要关注,机房需要部署良好的散热环境。