Oracle RMAN连接target报ora-01017的解决方法

在RAC的一个节点上使用rman通过tns(SCAN)连接时报错:

[oracle@rac1 ~]$ rman target system/system@orarac

Recovery Manager: Release 12.1.0.1.0 - Production on Mon Mar 23 13:35:40 2015

Copyright (c) 1982, 2013, Oracle and/or its affiliates. All rights reserved.

RMAN-00571: ===========================================================
RMAN-00569: =============== ERROR MESSAGE STACK FOLLOWS ===============
RMAN-00571: ===========================================================
RMAN-00554: initialization of internal recovery manager package failed
RMAN-04005: error from target database:
ORA-01017: invalid username/password; logon denied

而下面的连接没有问题:

[oracle@rac1 ~]$ rman target system/system

Recovery Manager: Release 12.1.0.1.0 - Production on Mon Mar 23 13:39:07 2015

Copyright (c) 1982, 2013, Oracle and/or its affiliates. All rights reserved.

connected to target database: ORARAC (DBID=377624869)

RMAN>

使用sys用户通过tns则可以连接:

[oracle@rac1 ~]$ rman target sys/system@orarac

Recovery Manager: Release 12.1.0.1.0 - Production on Mon Mar 23 13:41:11 2015

Copyright (c) 1982, 2013, Oracle and/or its affiliates. All rights reserved.

connected to target database: ORARAC (DBID=377624869)

RMAN>

我们给system用户授予sysdba权限测试一下:

[oracle@rac1 ~]$ sqlplus "/as sysdba"

SQL*Plus: Release 12.1.0.1.0 Production on Mon Mar 23 13:42:27 2015

Copyright (c) 1982, 2013, Oracle. All rights reserved.

Connected to:
Oracle Database 12c Enterprise Edition Release 12.1.0.1.0 - 64bit Production
With the Partitioning, Real Application Clusters, Automatic Storage Management, OLAP,
Advanced Analytics and Real Application Testing options

SQL> grant sysdba to system;

Grant succeeded.

再次在rman中使用system用户通过tns连接target:

[oracle@rac1 ~]$ rman target system/system@orarac

Recovery Manager: Release 12.1.0.1.0 - Production on Mon Mar 23 13:43:22 2015

Copyright (c) 1982, 2013, Oracle and/or its affiliates. All rights reserved.

connected to target database: ORARAC (DBID=377624869)

RMAN>

OK了(其实上面的测试也适用于远程使用rman连接target数据库),在这次测试中可以有下面的结论:

1、rman中(在远程机器或服务器上)使用tnsname连接target数据库时,需要用户具有SYSDBA权限;

2、rman中(在服务器上)不通过tnsname连接target数据库时,可以不需要SYSDBA权限;

阅读剩余