S9712 话机声音断断续续。
问题描述
【故障现象】S9712 接话机,ip电话,话机声音断断续续。【版本/补丁】【问题初步定位】【当前进展】【当前方案】【下一步计划】【已采集信息】(日志、诊断、配置等)【客户态度】
处理过程
设备收到了大量的STP TC报文,最近一次是从eth-trunk39收到的。
================================================
===============display stp ===============
================================================
-------[CIST Global Info][Mode MSTP]-------
CIST Bridge :32768.xxxx-xxxx-xxxx
Config Times :Hello 2s MaxAge 20s FwDly 15s MaxHop 20
Active Times :Hello 2s MaxAge 20s FwDly 15s MaxHop 20
CIST Root/ERPC :8192 .xxxx-xxxx-xxxx / 10000
CIST RegRoot/IRPC :32768.xxxx-xxxx-xxxx / 0 (This bridge is the root)
CIST RootPortId :128.691 (Eth-Trunk100)
BPDU-Protection :Disabled
TC or TCN received :2318797
TC count per hello :0
STP Converge Mode :Normal
Share region-configuration :Enabled
Time since last TC :0 days 0h:0m:7s
Number of TC :1521688
Last TC occurred :Eth-Trunk39
设备频繁收到STP TC报文,会频繁的做ARP 老化探测,可能会出现arp丢包,最后arp被老化,造成丢包。
建议排查下STP TC报文的来源。可以使用下面的命令行排查,看下哪些端口收到的STP TC报文比较多


此外,S9700的2/8/0/11频繁震荡,建议排查链路
Sep 27 2021 14:10:51+08:00 9712 %%01IFPDT/4/IF_STATE(l)[714]:Interface XGigabitEthernet2/8/0/11 has turned into UP state.
Sep 27 2021 14:10:50+08:00 9712 %%01IFPDT/4/IF_STATE(l)[715]:Interface XGigabitEthernet2/8/0/11 has turned into DOWN state.
Sep 27 2021 14:10:46+08:00 9712 %%01IFPDT/4/IF_STATE(l)[716]:Interface XGigabitEthernet2/8/0/11 has turned into UP state.
Sep 27 2021 14:10:44+08:00 9712 %%01IFPDT/4/IF_STATE(l)[717]:Interface XGigabitEthernet2/8/0/11 has turned into DOWN state.
Sep 27 2021 14:10:43+08:00 9712 %%01IFPDT/4/IF_STATE(l)[718]:Interface XGigabitEthernet2/8/0/11 has turned into UP state.
Sep 27 2021 14:10:37+08:00 9712 %%01IFPDT/4/IF_STATE(l)[719]:Interface XGigabitEthernet2/8/0/11 has turned into DOWN state.
Sep 27 2021 14:10:36+08:00 9712 %%01IFPDT/4/IF_STATE(l)[720]:Interface XGigabitEthernet2/8/0/11 has turned into UP state.
根因
设备频繁收到STP TC报文,会频繁的做ARP 老化探测,可能会出现arp丢包,最后arp被老化,造成丢包
解决方案
在接口上配置边缘端口后,问题解决