S5720在SVF组网中注册失败

问题描述

软件版本:

S7706软件版本: V200R008C00SPC500

S5720软件版本:v200r008c00spc500

组网概况:

两台S7706堆叠作为SVF组网的Parent、19台S5720做一级AS。

网络拓扑:

配置脚本:不涉及

故障现象:

一台S5720做为一级AS,两台S7706堆叠作为SVF组网的Parent,设备注册不成功。

查看AS注册状态:

<S7706>dis as all
Total: 18, Normal: 9, Fault: 1, Idle: 8, Version mismatch: 0
--------------------------------------------------------------------------------
No.  Type           MAC            IP              State        Name
--------------------------------------------------------------------------------
0    S5700S-LI      688f-8403-75f2 172.16.255.246  normal       as11
1    S5700S-LI      688f-8403-cbc8 172.16.255.249  normal       as22
2    S5700S-LI      688f-8403-75f7 172.16.255.250  normal       as21
3    S5700S-LI      688f-8403-75eb 172.16.255.247  normal       as31
4    S5700S-LI      688f-8403-cb3b 172.16.255.248  normal       as41
5    S5700S-LI      688f-8403-b4d4 172.16.255.251  normal       as32
6    S5700S-LI      688f-8403-b4c5 172.16.255.252  normal       as42
7    S5700-P-LI     688f-8404-fa74 --              idle         as51
8    S5700-P-LI     688f-8404-fb94 172.16.255.210  normal       as52
9    S5700-P-LI     688f-8404-fa73 --              idle         as53
10   S5700-P-LI     688f-8404-fe87 --              idle         as54
11   S5700-P-LI     688f-8404-fe35 --              idle         as55
12   S5700-P-LI     688f-8404-fa72 --              fault        as56
13   S5700-P-LI     688f-8404-fb95 --              idle         as57
14   S5700-P-LI     688f-8404-fa77 --              idle         as58
15   S5700-P-LI     688f-8404-fe30 172.16.255.253  normal       as59
16   S5700-P-LI     688f-8404-fe31 --              idle         as60
17   S5700-P-LI     48d5-391c-efc6 --              idle         as61
--------------------------------------------------------------------------------

 

告警信息

<S7706>

Sep 18 2017 14:02:06 S7706
MBR/5/CONNECTERROR:OID 1.3.6.1.4.1.2011.5.25.327.31.3.2.1 Connection error on
the fabric-port in unified management. (Reason=Input has been detected in the
client.(GigabitEthernet6/0/14))

处理过程

1、在S5720 AS上执行reset vcmp命令;

2、在S5720 AS上执行命令undo uni-mng enable;

3、重启S5720。

查看设备注册状态:

<S7706>dis as all
Total: 18, Normal: 9, Fault: 1, Idle: 8, Version mismatch: 0
--------------------------------------------------------------------------------
No.  Type           MAC            IP              State        Name
--------------------------------------------------------------------------------
0    S5700S-LI      688f-8403-75f2 172.16.255.246  normal       as11
1    S5700S-LI      688f-8403-cbc8 172.16.255.249  normal       as22
2    S5700S-LI      688f-8403-75f7 172.16.255.250  normal       as21
3    S5700S-LI      688f-8403-75eb 172.16.255.247  normal       as31
4    S5700S-LI      688f-8403-cb3b 172.16.255.248  normal       as41
5    S5700S-LI      688f-8403-b4d4 172.16.255.251  normal       as32
6    S5700S-LI      688f-8403-b4c5 172.16.255.252  normal       as42
7    S5700-P-LI     688f-8404-fa74 --              idle         as51
8    S5700-P-LI     688f-8404-fb94 172.16.255.210  normal       as52
9    S5700-P-LI     688f-8404-fa73 --              idle         as53
10   S5700-P-LI     688f-8404-fe87 --              idle         as54
11   S5700-P-LI     688f-8404-fe35 --              idle         as55
12   S5700-P-LI     688f-8404-fa72 --              fault        as56
13   S5700-P-LI     688f-8404-fb95 --              idle         as57
14   S5700-P-LI     688f-8404-fa77 --              idle         as58
15   S5700-P-LI     688f-8404-fe30 172.16.255.253  normal       as59
16   S5700-P-LI     688f-8404-fe31 --              idle         as60
17   S5700-P-LI     48d5-391c-efc6 172.16.255.245  normal       as61
--------------------------------------------------------------------------------

 

根因

1、AS存在VCMP同步VLAN;

2、AS已经强制配置为Client模式。

解决方案

1、AS存在VCMP同步VLAN;在AS上执行reset vcmp命令;

2、AS已经强制配置为Client模式;在Parent上配置连接该AS的Fabric-port为非直连模式,或者在AS上执行命令undo uni-mng enable并重启AS退出强制Client模式。

建议与总结

1、SVF组网中AS注册时,启动后不要立刻登录串口。