S5700 PoE接某友商AP不供电
问题描述
告警信息
无
处理过程
1、检查是否支持POE供电,客户反馈设备型号是S5700S-28P-PWR-LI-AC,确认支持POE供电
2、进入接口查看信息,无法判断PD状态:
[HUAWEI-diagnose]interface gigabitethernet0/0/1
[HUAWEI-GigabitEthernet0/0/1]poe legacy enable
[HUAWEI-GigabitEthernet0/0/1]display this
#
interface GigabitEthernet0/0/1
poe legacy enable
#
return
[HUAWEI-GigabitEthernet0/0/1]q
[HUAWEI]lldp enable
Info: Global LLDP is enabled successfully.
[HUAWEI]
Dec 5 2017 09:17:31 HUAWEI LLDP/4/ADDCHGTRAP:OID 1.3.6.1.4.1.2011.5.25.134.2.5 Local management address is changed. (LocManAddr=48d5-391a-e6c0)
[HUAWEI]
Dec 5 2017 09:17:31 HUAWEI LLDP/4/ENABLETRAP:OID 1.3.6.1.4.1.2011.5.25.134.2.1 Global LLDP is enabled.
[HUAWEI]
Dec 5 2017 09:17:39 HUAWEI DS/4/DATASYNC_CFGCHANGE:OID 1.3.6.1.4.1.2011.5.25.191.3.1 configurations have been changed. The current change number is 4, the change loop count is 0, and the maximum number of records is 4095.
[HUAWEI]
Dec 5 2017 09:17:53 HUAWEI LLDP/4/NBRCHGTRAP:OID 1.0.8802.1.1.2.0.0.1 Neighbor information is changed. (LldpStatsRemTablesInserts=1, LldpStatsRemTablesDeletes=0, LldpStatsRemTablesDrops=0, LldpStatsRemTablesAgeouts=0)lldp enable
[HUAWEI-GigabitEthernet0/0/1]lldp dot3-tlv power 802.3at
[HUAWEI-GigabitEthernet0/0/1]d
Dec 5 2017 09:22:29 HUAWEI DS/4/DATASYNC_CFGCHANGE:OID 1.3.6.1.4.1.2011.5.25.191.3.1 configurations have been changed. The current change number is 5, the change loop count is 0, and the maximum number of records is 4095.
[HUAWEI-GigabitEthernet0/0/1]display this
#
interface GigabitEthernet0/0/1
poe legacy enable
lldp dot3-tlv power 802.3at
3、客户提供POE适配器查看,输出电压是24V,电流1000mA
4、华为5700交换机采用的802.3at供电标准,对PD的要求如下:
5、可以看出客户采用的AP是非标AP,不满足802.3at输出电压37-42.5V。因此华为S5700无法给友商AP供电。
根因
客户采用的AP是非标AP,不满足802.3at输出电压37-42.5V。因此华为S5700无法给友商AP供电。