S6720 V2R11C10与VRM云服务器eth-trunk对接修改掩码故障

-

问题描述

故障前:s6720 g0/0/1-g0/0/4通过eth-trunk30\eth-trunk40与VRM云服务器对接,透传vlan100、vlan102,

网关在交换机vlanif100:172.16.100.254 255.255.255.0,Vlanif102:172.16.102.253 255.255.255.0

修改掩码:

1、修改交换机vlanif100、valnif102掩码为23位,业务运行正常

2、修改VRM云服务器vlanif100掩码根交换机同步后,业务中断

3、恢复交换机s6720及VRM云服务器vlanif100、vlanif102掩码为24位后互ping不通

 

告警信息

处理过程

1、把所有加入eth-trunk接口全部down,然后up,依然不通

2、分析交换机诊断信息,无告警,配置无异常

交换机侧:

interface Vlanif100
description fuwuqi
ip address 172.16.100.254 255.255.255.0

interface Vlanif102
ip address 172.16.102.253 255.255.255.0

interface Eth-Trunk30
description cna01
port link-type trunk
port trunk allow-pass vlan 2 to 4094
load-balance src-dst-mac

interface Eth-Trunk40
description cna02
port link-type trunk
port trunk allow-pass vlan 2 to 4094
load-balance src-dst-mac

interface GigabitEthernet0/0/1
eth-trunk 30

interface GigabitEthernet0/0/2
eth-trunk 30

interface GigabitEthernet0/0/3
eth-trunk 40

interface GigabitEthernet0/0/4
eth-trunk 40

服务器侧:

2.png

3、做流量统计,入方向没有流量

3.png

4、专家远程接入查看交换机侧无异常

5、云平台工程师远程接入观察,最后发现云平台缺省vlan变成了vlan0,不透传vlan,导致云平台与交换机不通

6、再次修改掩码测试,发现云服务器只要修改vlanif掩码,云平台透传vlan就自动回到缺省值vlan0

根因

修改vlanif掩码,VRM云平台透传vlan回到缺省值vlan0,导致vlan无法透传

解决方案

手动修改VRM云平台透传vlan为vlan100、vlan102,问题解决